CORENET X Notes (official rules & actual values — reference)
Verbatim capture of CORENET X Notes — official-page rules, notes and Actual Values tables not carried by the CoP-derived corpus. Reference only — rules are NOT allowed_values; actual_values record official vocabulary the CoP leaves free-input. Official typos are kept verbatim and flagged [sic]. Gateway/submission-process domain content (Design Gateway/CG/DG, PWCS, parking-provision policy) is deliberately excluded per owner decision.
62 entries across 34 components (30 rule, 28 note, 4 actual_values; 6 borderline).
Beam
- rule · scope: component
- Multiple beams elements shall be modelled from support to support for beams with continuous spans.
Borehole
- rule · scope: component
- The SI report for all boreholes shall be included and submitted in PDF & AGS format.
- rule · scope: component
- The borehole elements shall be modelled as per true coordinates in the IFC+SG structural model with the necessary information required as stipulated in the tables below.
Breeching Inlet
- note · scope: component
- Besides modelling the individual Breeching Inlet as an individual component, also ensure each Breeching Inlet is exported as part of the Dry Riser, Wet Riser, Foam Sprinkler or Sprinkler System respectively.
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Building Storey
- rule · scope: component
- All disciplines must have be aligned in naming and z-value of the building storeys when geo-referencing their models for coordination.
- 'must have be' is an official grammar error [sic]
- rule · scope: component · borderline
- Roof level is required to be separately represented as a property to meet URA requirements
Column
- rule · scope: component
- Column working load is required for 1st storey column only.
- rule · scope: component
- Multiple columns elements shall be modelled from support to support (storey to storey) for continuous column.
Culvert/ Drains
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Damper
- note · scope: component · borderline
- Refer here for fire safety equipment / provisions that need not be modelled in full and can be represented by suitable modelling objects / components.
- rule · scope: component
- Modelling Damper is voluntary.
Distribution Chamber
- rule · scope: property
- Depth, TopLevel and InvertLevel shall be accurately provided in the model.
- rule · scope: component
- Internal dimensions shall be accurately provided in the model.
- rule · scope: component
- Manhole ID shall be provided for manhole within the model.
- note · SystemType (printed "System Type" [sic]) · scope: property
- Refer to System for full list of system types that can be provided under "System Type" property.
Door
- rule · ClearHeight · scope: property
- All the door elements must indicate "ClearHeight" in its properties, to facilitate headroom checks.
Foam Inlet / Outlet
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Footing / Pilecap
- rule · scope: component
- All the footing / pilecap elements shall be modelled as independent elements* in IFC+SG model with the necessary information required as stipulated in the tables below.
Grating
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Green Verges
- note · scope: component · borderline
- Hence, please ensure that the soil depth shown in the model is at least 2.0m.
Gutter
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Interceptor
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Lamp Post
- rule · scope: component
- Only lamp post within the site boundary will need to be modelled, using placeholder objects. It is not necessary to replicate details of actual lamp posts.
Landscape Plants
- rule · Girth · scope: property
- Girth value shall be accurately input.
Pile
- rule · scope: component
- For pile performance-based design, the project team must submit separate sets of IFC+SG models for each distinct pile design parameter.
- rule · scope: component
- The pile elements shall be modelled as per true coordinates in the IFC+SG model with the necessary information required as stipulated in the tables below.
Pipes/ Ducts
- note · scope: component
- Sanitary drain-lines are to be submitted as schematic and/or 2D drawings. If industry would like to submit in 3D, it is optional and will also be accepted.
- rule · scope: property
- InnerDiameter, NominalDiameter and Thickness of Pipes shall be accurately provided.
- rule · scope: component
- Pipe size, location and gradient shall be accurately modelled.
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Planting Areas
- note · scope: component · borderline
- Hence, please ensure that the soil depth shown in the model is at least 2.0m.
Prefabricated Building Systems and MEP Components
- note · scope: component
- Every element in the M&E system in the BIM models can be identified via a unique system name with a system classification based on the two key parameters "SystemName" and "SystemType".
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Project Development Type
- rule · ProjectDevelopmentType · scope: model
- Only one Project Development Type property applies to the entire IFC model
Pump
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Sanitary Appliances
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Seating
- note · scope: component · borderline
- To determine Occupancy Load for Assembly Spaces (e.g. Auditorium, Theatre), it is necessary to indicate the type of seating
Space
- rule · scope: model · borderline
- AVF_IncludeAsGFA must be checked for all areas that are proposed to be included as GFA and AGF_DevelopmentUse must be keyed in for all areas in relation to GFA evaluation.
- rule · scope: model
- They shall be exported to Space with IFC Sub-type "AREA_GFA".
Space (Area Requirements)
- rule · scope: property
- Below recommended values for AGF_Names sorted based on their associated development use. These values shall be used as much as possible before alternatives are considered.
- actual_values · ALS_GreeneryFeatures · scope: property
- Green Buffer; Peripheral Planting Verge; Landscape Deck - Vertical Greenery; Landscape Deck - Surface Greenery; Communal Ground Garden; Sky Terrace; Roof Top Landscaping; Ground Landscaping; Urban Farm / Greenhouse; Vertical Greenery; Extensive Green Roof; Green Verge
- actual_values · ALS_LandscapeType · scope: property
- Turfing; Groundcovers; Shrubs; Decked / Patterened Floor; Water Feature; Landscaped Footpath; Playground; BBQ Pit
- 'Decked / Patterened Floor' is an official typo for 'Patterned' [sic]; the 'Shrubs' value carries footnote 1 (see the note entry).
- note · ALS_LandscapeType · scope: property
- Note that Shurbs will include both within Site Boundary and outside Site Boundary (in Green Verge)
- 'Shurbs' is an official typo for 'Shrubs' [sic]; footnote 1 annotating the ALS_LandscapeType 'Shrubs' value.
- actual_values · ALS_Species · scope: property
- Ophiopogon jaburan (Example); Codiaeum variegatum (Example); Dracaena marginata (Example); Murraya paniculata (Example)
- example-only — each value is tagged '(Example)' on the page; not a closed list.
- actual_values · AVF_IncludeAsGFA · scope: property
- Yes; No
- the page states the type as '[Booelan]' [sic] (Boolean) and renders the values as a single 'Yes / No' cell; the corpus renders Booleans as TRUE / FALSE — discrepancy recorded in crosscheck.
Space (Usage)
- note · scope: component
- For toilet or shower clusters, accessible toilet or shower cubicles shall be modelled as a separate space from the rest of the toilet clusters.
- rule · scope: component
- *** All Ramp Spaces must include modelling of ramp components (IfcRamp).
- rule · scope: component
- Every space in the development shall be modelled and tagged as a space in the BIM model.
- rule · scope: component
- The space shall start from dominant FFL of the space or lowest FFL.
- rule · scope: component
- Every space component should include inputs for both Occupancy Type and Space Name parameters.
- rule · scope: component
- Spaces across BCA, LTA, NEA, PUB, and SCDF have been harmonized and standardized for checks into Occupancy Types and Space Name categories.
- rule · scope: component
- Thus, all Spaces should be accompanied by both Space Name and Occupancy Type parameters.
Sprinkler (Non-Fire; For NEA)
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
System
- note · scope: component
- The Foam Fire Extinguishing System should include Foam Inlet and Foam Outlet components.
- note · scope: component
- The Foam Sprinkler System and Sprinkler System should include Breeching Inlet components.
- note · scope: component
- The Wet Riser System and Dry Riser System should include Breeching Inlet and Landing Valve components.
Valve
- note · scope: component
- Ensure the Landing Valve is also exported as part of the Wet Riser System and Dry Riser System
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Wall
- rule · scope: component
- Multiple wall elements shall be modelled from storey to storey for continuous wall.
Waste Terminal
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.
Water Meter
- note · SystemType · scope: property
- Refer to System for full list of system types that can be provided under "SystemType" property.