Column — Notes
Provenance
- Source: CORENET X Code of Practice v3.1, Section 4 (BIM Data Representation — IFC+SG), pages 21–24.
- Source link: CORENET X — IFC-SG Glossary of Identified Components ↗
- Discipline: ARC · Authorities: BCA, URA, SCDF, LTA, NParks, PUB, NEA
- 1 IFC binding(s), 25 parameter(s).
IFC binding breakdown
IfcColumn— 25 param(s), table format7col.
Element-type segmentation (applies_to)
- Steel column: 6 parameter(s)
- When required / relevant: 6 parameter(s)
- All columns: 5 parameter(s)
- RC column: 5 parameter(s)
Input-limited parameters resolved against structural enums
- ConnectionTypeBottom (structural_enums (p3)): Pinned, Fixed, Free
- ConnectionTypeTop (structural_enums (p3)): Pinned, Fixed, Free
- ConstructionMethod (structural_enums (p3)): CIS, PC, PT (Pre), PT (Post), PF, PPVC, Spun [for pile element only]
- MaterialGrade (structural_enums (p3) Footnote marker '*' stripped 2026-08-08; captured on the MaterialGrade group in _reference/structural_enums.json (CoP v3.1 PDF p.249).): C12/15, C20/25, C30/37, C32/40, C35/45, C40/50, C50/60, C55/67, C60/75, C70/85, C80/95, S235, S275, S355, S460
- ReinforcementSteelGrade (structural_enums (p3)): 500A, 500B, 500C, 600A, 600B, 600C
- SectionFabricationMethod (structural_enums (p3)): Hot rolled, Cold formed
- StirrupsType (structural_enums (p3)): Normal, U, C, CL [for civil defence shelter], Torsion
Other input-limited parameters
These accept values from a defined list in the COP source table (not part of the global structural enums); see examples in parameters.json:
- MechanicalConnectionType, PrefabricatedReinforcementCage