corenetx.md
Component
Culvert/ Drains
Discipline
ARC
Authorities
BCA, PUB
Pages
26–26
Source
CORENET X Code of Practice v3.1 — source ↗

IfcCivilElement COMMONDRAIN, CROSSCULVERT, CULVERT, ENTRANCECULVERT, EXTERNALDRAIN, INTERNALDRAIN, OUTLETDRAIN, ROADSIDEDRAIN, TRENCH

S/NPropertyTypeUnitLimitedValues / Examples
1DiameterLengthmm
2GradientText
3HeightLengthmm
4LengthLengthmm
5LoadBearingBooleanYesTRUEFALSEe.g. TRUE / FALSE
6MaterialText
7SystemNameText
8SystemTypeTextSanitaryKitchen Fresh AirSewerageParking Place Exhaust AirDrainageStaircase Pressurisation AirRainwaterGenset Exhaust AirPotable WaterPollution Control Equipment Exhaust AirSprinklerKitchenhood Exhaust AirFoam SprinklerPWCS Fresh AirFoam Fire ExtinguishingWet RiserDry RiserTrade Effluente.g. Rainwater, Drainage⚑ Refer to System for full list of system types that can be provided under "SystemType" property.
9ThicknessLengthmm
10WidthLengthmm

IfcBuildingElementProxy DROPINLETCHAMBER declarative · no properties required