Refuse Chute / Recyclables Chute — Notes
Provenance
- Source: CORENET X Code of Practice v3.1, Section 4 (BIM Data Representation — IFC+SG), pages 87–89.
- Source link: CORENET X — IFC-SG Glossary of Identified Components ↗
- Discipline: ARC · Authorities: NEA
- 4 IFC binding(s), 26 parameter(s).
IFC binding breakdown
IfcSpace— subtypes: SPACE — 7 param(s), table format6col.IfcWall— subtypes: REFUSECHUTE — 1 param(s), table format6col.IfcDoor— subtypes: ACCESSHATCH, RECYCLABLESCHUTEACCESSPANEL, RECYCLABLESCHUTEHOPPER, REFUSECHUTEACCESSPANEL, REFUSECHUTEHOPPER — 10 param(s), table format6col.IfcTank— subtypes: REFUSECONTAINER, REFUSECOMPACTOR, RECYCLABLECONTAINER, RECYCLABLECOMPACTOR — 8 param(s), table format6col.
Input-limited parameters resolved against structural enums
- ConstructionMethod (structural_enums (p3)): CIS, PC, PT (Pre), PT (Post), PF, PPVC, Spun [for pile element only]
Other input-limited parameters
These accept values from a defined list in the COP source table (not part of the global structural enums); see examples in parameters.json:
- SpaceName, AirTight, SelfClosing, VolumeControlled, EquipmentType