# Sanitary Appliances — Notes

## Provenance

- Source: **CORENET X Code of Practice v3.1**, Section 4 (BIM Data Representation — IFC+SG), pages 94–96.
- Source link: [CORENET X — IFC-SG Glossary of Identified Components ↗](https://info.corenet.gov.sg/ifc-sg/bim-data-(ifc-sg)/glossary-of-identified-components?id=6d62f810-d9b7-4b4e-8f15-719099f51147)
- Discipline: **ARC**  ·  Authorities: **BCA, PUB**
- 6 IFC binding(s), 29 parameter(s).

## IFC binding breakdown

- `IfcSanitaryTerminal` — subtypes: BATH — 3 param(s), table format `6col`.
- `IfcSanitaryTerminal` — subtypes: BIDET — 3 param(s), table format `6col`.
- `IfcSanitaryTerminal` — subtypes: SHOWER — 3 param(s), table format `6col`.
- `IfcSanitaryTerminal` — subtypes: URINAL — 7 param(s), table format `6col`.
- `IfcSanitaryTerminal` — subtypes: WASHHANDBASIN — 5 param(s), table format `6col`.
- `IfcSanitaryTerminal` — subtypes: WATERCLOSET — 8 param(s), table format `6col`.

## Other input-limited parameters

These accept values from a defined list in the COP source table (not part of the global structural enums); see `examples` in `parameters.json`:

- WELS, AmbulantDisabled, ChildrenFriendly, Waterless, BarrierFreeAccessibility, ToiletPanType