⚑ CORENET X Notes
For toilet or shower clusters, accessible toilet or shower cubicles shall be modelled as a separate space from the rest of the toilet clusters.
*** All Ramp Spaces must include modelling of ramp components (IfcRamp).
Every space in the development shall be modelled and tagged as a space in the BIM model.
The space shall start from dominant FFL of the space or lowest FFL.
Every space component should include inputs for both Occupancy Type and Space Name parameters.
Spaces across BCA, LTA, NEA, PUB, and SCDF have been harmonized and standardized for checks into Occupancy Types and Space Name categories.
Thus, all Spaces should be accompanied by both Space Name and Occupancy Type parameters.
IfcSpace SPACE
| S/N | Property | Type | Unit | Limited | Values / Examples |
|---|---|---|---|---|---|
| 1 | Accreditation_MAS | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 2 | Area | Area | m2 | — | — |
| 3 | AmbulantDisabled | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 4 | BarrierFreeAccessibility | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 5 | ChildrenFriendly | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 6 | CValue | Text | — | — | e.g. 0.45 - 1 |
| 7 | ElderlyFriendly | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 8 | EmergencyVoiceCommunicationSystem | Text | — | Yes | 1-way EVC System2-way EVC SystemPublic Address Systeme.g. 1-way EVC System, 2-way EVC System, Public Address System. |
| 9 | FireDetectionAndSuppressionSystem | Text | — | Yes | Automatic Fire Alarm SystemAutomatic Sprinkler SystemWater Mist SystemVideo Image Fire Detector SystemKitchen Hood Fire Extinguishing SystemClean Agent Fire Extinguishing SystemAutomatic Foam Sprinkler SystemFoam Extinguisher Systeme.g. Automatic Fire Alarm System, Automatic Sprinkler System, Water Mist System, Video Image Fire Detector System, Kitchen Hood Fire Extinguishing System, Clean Agent Fire Extinguishing System, Automatic Foam Sprinkler System, Foam Extinguisher System |
| 10 | FireEmergencyVentilationMode | Text | — | Yes | Natural VentilationMechanical VentilationPressurisationCross-ventilationCross-ventilation with Intermediate Ventilation OpeningVapour Extraction System (for spray painting room)e.g. Natural Ventilation, Mechanical Ventilation, Pressurisation, Cross-ventilation, Cross-ventilation with Intermediate Ventilation Opening, Vapour Extraction System (for spray painting room) |
| 11 | FireExit | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 12 | FullyCoveredWithTreesShrubs | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 13 | HearingEnhancement | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 14 | Height | Length | mm | — | — |
| 15 | LargerAccessible | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 16 | OccupancyLoad | Real | — | — | — |
| 17 | OccupancyType | Text | — | Yes | Single dwelling residentialMulti-unit residentialSupervisory care facilitySupervisory care facility (detention)Nursing care facilitiesHospital with A&E servicesHospital without A&E servicesAmbulatory care facilityAmbulatory care facility (standalone)Custodian care facilityPrimary schoolSecondary schoolCustodian care facility (nursery)Tertiary Education InstitutionPublic education institutionPrivate education institutionTuition centreWorker dormitoryOfficeTelephone Exchange/ Central OfficeFactory officeShopOutdoor Display Area (ODA)Outpatient clinic+71 more official values (full list in parameters.json)e.g. Refer to list of Occupancy Types in Modelling IFC+SG (Space Usage) |
| 18 | ParkingType | Text | — | — | e.g. Bicycle, Motorcycle |
| 19 | PurposeGroup | Text | — | — | e.g. I, II, III |
| 20 | RefuseOutput | Real | — | — | e.g. 120, 200- |
| 21 | Retrofit | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 22 | SmokeControlSystem | Text | — | Yes | Smoke VentSmoke Purging SystemDuctless Jet Fan SystemEngineered Smoke Control Systeme.g. Smoke Vent, Smoke Purging System, Ductless Jet Fan System, Engineered Smoke Control System |
| 23 | SoundPowerLevel | Text | — | — | — |
| 24 | SoundPressureLevel | Text | — | — | — |
| 25 | SpaceName | Text | — | Yes | BalconyBedroomMaster BedroomMaid RoomGuestroomBathroomMaster BathMaid BathYard BathDining RoomDining AreaHousehold ShelterKitchenLiving RoomLiving AreaLoftPrivate Lift LobbyPrivate Enclosed SpaceService YardStudyToiletWalk-in WardrobeStudent Bedroom IndividualStudent Bedroom Multipax+397 more official values (full list in parameters.json)e.g. Refer to list of Space Names in Modelling IFC+SG (Space Usage) |
| 26 | StepRampAccess | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 27 | TwentyFourHourMannedStation | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 28 | UnitNumber | Text | — | — | — |
| 29 | VentilationMode | Text | — | Yes | Natural VentilationAir ConditioningMechanical Ventilatione.g. Natural Ventilation, Air Conditioning, Mechanical Ventilation, Mechanical Ventilation |
| 30 | VentilationType | Text | — | — | e.g. Cross Ventilation |
| 31 | Volume | Volume | m3 | — | — |
Machine API: parameters.json — raw README.md / notes.md