corenetx.md
Component
Distribution Chamber
Discipline
MEP
Authorities
NEA
Pages
29–30
Source
CORENET X Code of Practice v3.1 — source ↗
⚑ CORENET X Notes

Depth, TopLevel and InvertLevel shall be accurately provided in the model.

Internal dimensions shall be accurately provided in the model.

Manhole ID shall be provided for manhole within the model.

IfcDistributionChamberElement INSPECTIONCHAMBER, MANHOLE, METERCHAMBER, PWCSINSPECTIONCHAMBER, PWCSMANHOLE, SCREENCHAMBER, SAMPLINGSUMP, SUMP, TRENCH

S/NPropertyTypeUnitLimitedValues / Examples
1TopLevelTextSHD me.g. -50, 3.423
2InvertLevelTextSHD m
3DiameterLengthmm
4DepthLengthmm
5HeightLengthmm
6LengthLengthmm
7WidthLengthmm
8MaterialText
9TradeEffluentBooleanYesTRUEFALSEe.g. TRUE / FALSE
10IDText
11StatusTextYesTemporaryDemolishedExistingProposedTo Be RemovedTo Be TransplantedAbandonedNewe.g. Temporary, Demolished, Existing, Proposed, To Be Removed, To Be Transplanted, Abandoned, New
12SystemTypeTextSanitaryKitchen Fresh AirSewerageParking Place Exhaust AirDrainageStaircase Pressurisation AirRainwaterGenset Exhaust AirPotable WaterPollution Control Equipment Exhaust AirSprinklerKitchenhood Exhaust AirFoam SprinklerPWCS Fresh AirFoam Fire ExtinguishingWet RiserDry RiserTrade Effluente.g. Sanitary, Sewerage⚑ Refer to System for full list of system types that can be provided under "System Type" property.
13SystemNameText

IfcCovering PWCSINSPECTIONCHAMBERCOVER, PWCSMANHOLECOVER

S/NPropertyTypeUnitLimitedValues / Examples
1WatertightBooleanYesTRUEFALSEe.g. TRUE / FALSE
2ExternalReferenceTexte.g. SS 30 Manhole Tops and Surface-box Tops

Machine API: parameters.json — raw README.md / notes.md