⚑ CORENET X Notes
Depth, TopLevel and InvertLevel shall be accurately provided in the model.
Internal dimensions shall be accurately provided in the model.
Manhole ID shall be provided for manhole within the model.
IfcDistributionChamberElement INSPECTIONCHAMBER, MANHOLE, METERCHAMBER, PWCSINSPECTIONCHAMBER, PWCSMANHOLE, SCREENCHAMBER, SAMPLINGSUMP, SUMP, TRENCH
| S/N | Property | Type | Unit | Limited | Values / Examples |
|---|---|---|---|---|---|
| 1 | TopLevel | Text | SHD m | — | e.g. -50, 3.423 |
| 2 | InvertLevel | Text | SHD m | — | — |
| 3 | Diameter | Length | mm | — | — |
| 4 | Depth | Length | mm | — | — |
| 5 | Height | Length | mm | — | — |
| 6 | Length | Length | mm | — | — |
| 7 | Width | Length | mm | — | — |
| 8 | Material | Text | — | — | — |
| 9 | TradeEffluent | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 10 | ID | Text | — | — | — |
| 11 | Status | Text | — | Yes | TemporaryDemolishedExistingProposedTo Be RemovedTo Be TransplantedAbandonedNewe.g. Temporary, Demolished, Existing, Proposed, To Be Removed, To Be Transplanted, Abandoned, New |
| 12 | SystemType | Text | — | — | SanitaryKitchen Fresh AirSewerageParking Place Exhaust AirDrainageStaircase Pressurisation AirRainwaterGenset Exhaust AirPotable WaterPollution Control Equipment Exhaust AirSprinklerKitchenhood Exhaust AirFoam SprinklerPWCS Fresh AirFoam Fire ExtinguishingWet RiserDry RiserTrade Effluente.g. Sanitary, Sewerage⚑ Refer to System for full list of system types that can be provided under "System Type" property. |
| 13 | SystemName | Text | — | — | — |
IfcCovering PWCSINSPECTIONCHAMBERCOVER, PWCSMANHOLECOVER
| S/N | Property | Type | Unit | Limited | Values / Examples |
|---|---|---|---|---|---|
| 1 | Watertight | Boolean | — | Yes | TRUEFALSEe.g. TRUE / FALSE |
| 2 | ExternalReference | Text | — | — | e.g. SS 30 Manhole Tops and Surface-box Tops |