Prefabricated Building Systems and MEP Components — Notes
Provenance
- Source: CORENET X Code of Practice v3.1, Section 4 (BIM Data Representation — IFC+SG), pages 80–81.
- Source link: CORENET X — IFC-SG Glossary of Identified Components ↗
- Discipline: MEP · Authorities: —
- 8 IFC binding(s), 29 parameter(s).
IFC binding breakdown
IfcSpace— subtypes: PREFABRICATEDBATHROOMUNIT, PREFABRICATEDANDPREFINISHEDWALL, PREFABRICATEDANDPREFINISHEDFLOOR, PREFABRICATEDANDPREFINISHEDCEILING, PRECASTEXTERNALWALLWITHCAST-INWINDOWS, PREFABRICATEDPUMPSKID, PREFABRICATEDMEPVERTICALMODULE, PREFABRICATEDMEPPLANTMODULE, PREFABRICATEDMEPHORIZONTALMODULE — 6 param(s), table format6col.IfcWall— 2 param(s), table format6col.IfcSlab— 2 param(s), table format6col.IfcPipeFitting— subtypes: RIGIDSEGMENT, FLEXIBLESEGMENT — 4 param(s), table format6col.IfcPipeSegment— subtypes: RIGIDSEGMENT, FLEXIBLESEGMENT — 4 param(s), table format6col.IfcDuctFitting— 4 param(s), table format6col.IfcDuctSegment— 4 param(s), table format6col.IfcDiscreteAccessory— subtypes: PIPESUPPORT — 3 param(s), table format6col.
Input-limited parameters resolved against structural enums
- ConstructionMethod (structural_enums (p3)): CIS, PC, PT (Pre), PT (Post), PF, PPVC, Spun [for pile element only]
Other input-limited parameters
These accept values from a defined list in the COP source table (not part of the global structural enums); see examples in parameters.json:
- SpaceName, Accreditation_MAS, PreInsulated, SystemType, IsCommon