# Footing / Pilecap

| Field | Value |
| --- | --- |
| Discipline | STR |
| Authorities | — |
| Pages (COP v3.1) | 46–51 |
| IFC Bindings | 1 |
| Parameters | 19 |
| Source | CORENET X Code of Practice v3.1 |
| Source link | [View on CORENET X ↗](https://info.corenet.gov.sg/ifc-sg/bim-data-(ifc-sg)/glossary-of-identified-components?id=e469ae03-80ba-41b4-970d-a11f36618ace) |

## IFC Bindings

| # | IFC Entity | Predefined subtype(s) | Params | Notes |
| --- | --- | --- | --- | --- |
| 1 | `IfcFooting` | — | 19 |  |

## Parameters

See `parameters.json` for the machine-readable, binding-grouped data (with resolved `allowed_values` for input-limited fields).

| IFC Entity | S/N | Property | Type | Unit | Input limited | Example |
| --- | --- | --- | --- | --- | --- | --- |
| `IfcFooting` | 1 | DA1-1_BearingCapacity | Integer | kN/m2 |  | 150 |
| `IfcFooting` | 2 | DA1-2_BearingCapacity | Integer | kN/m2 |  | 120 |
| `IfcFooting` | 3 | ReferTo2DDetail | Text |  |  | Dwg Number |
| `IfcFooting` | 4 | ReinforcementSteelGrade | Text |  | Y | Refer to list^ |
| `IfcFooting` | 5 | SoilVerificationTest | Text |  |  | 2 nos Plate load Test |
| `IfcFooting` | 6 | Breadth | Length | mm |  | 6200 |
| `IfcFooting` | 7 | Depth | Length | mm |  | 300 |
| `IfcFooting` | 8 | Mark | Text |  |  | F1; F2; PC1; PC2; PC4_1 |
| `IfcFooting` | 9 | Width | Length | mm |  | 300 |
| `IfcFooting` | 10 | BottomDistribution | Text |  |  | H16-150 |
| `IfcFooting` | 11 | BottomMain | Text |  |  | H25-150 |
| `IfcFooting` | 12 | SideBar | Text |  |  | H13-250 |
| `IfcFooting` | 13 | Stirrups | Text |  |  | H13-200-300 |
| `IfcFooting` | 14 | StirrupsType | Text |  | Y | Refer to list^ |
| `IfcFooting` | 15 | TopDistribution | Text |  |  | H16-150 |
| `IfcFooting` | 16 | TopMain | Text |  |  | H25-150 |
| `IfcFooting` | 17 | WorkingLoad_DA1-1 | Integer | kN |  | 4321 |
| `IfcFooting` | 18 | WorkingLoad_DA1-2 | Integer | kN |  | 4321 |
| `IfcFooting` | 19 | MaterialGrade | Text |  | Y | Refer to list^ |